Call Us
Call Us
+919818254996
E-mail Us
Email
vikashjain@asiatic-india.com
Change Language
Expulsion Fuse Cutouts

Expulsion Fuse Cutouts

Product Details:

X

Expulsion Fuse Cutouts Price And Quantity

  • 100 Number

Expulsion Fuse Cutouts Trade Information

  • 100 Number Per Month
  • 8-10 Week

Product Description

The Expulsion Fuse Cutouts consist of a reliable mechanism. It is used for protecting Arial distribution systems for voltages ranging from11 kV to 36 kV. It is designed to be installed outdoors for vertical cross arm or pole mounting. These cutouts are available in both Porcelain & Silicone rubber insulators. the Expulsion Fuse Cutouts has steel hooks mounted on the top support guide into the contact and also serves a dual purpose for use with load break tools. The holder has clearly distinguished outer layer of UV resistant fibre glass and inner layer of bone liner which effectively extinguishes the Arc.

Features:
  • The fuse carrier tube is replaceable with a new one in an unlikely event of being damaged or burnt.
  • The hinged mechanism is made from brass and is duly electroplated ensuring smooth operation in corrosive environments and provides low resistance current transfer path.
  • With the incorporation of Arc Shortening rod, higher interruption capacity is achievable. The Arc Shortening rod is optional and is available on request.
Expulsion Fuse Cutouts:
  • It has a safety latch which prevents the fuse carrier from dropping due to vibration. 
  • It can be used as off load disconnector with Brass Blade instead of Fuse holder.
  • The upper and lower Eye bolt connectors are provided with the cutout.
  • The unit is supplied with mounting brackets duly galvanized with necessary hardware for fixing in intended location.
  • The expulsion fuse cutouts are available in both Porcelain and Silicone rubber insulators.

Technical specification

SPECIFICATIONS

PORCELAIN

SILICONE RUBBER

CATALOUGE REF.

A36AD

A12AD

A-36ASR; A-24ASR; A-12ASR

TYPE

A 0R 2 A

A OR 2

A OR 2

RATEDVOLTAGE

36kV

12kV

36 kV; 24 kV; 12 kV

RATED CONTINUOUS CURRENT

100 AMP

100 AMP

100 AMP

MAXIMUM NORMAL CURRENT OF FUSE BASE

200 AMP

200 AMP

200 AMP

MAXIMUM NORMAL CURRENT OF FUSE HOLDER

100 AMP

100 AMP

100 AMP

RATED FREQUENCY

50 Hz

50 Hz

50 Hz

LIGHTNING IMPULSE WITHSTANDVOLTAGE

A) ACROSS THE ISOLATING DISTANCE OF THE FUSE BASE

B) TO EARTH AND BETWEEN POLES

195 kV

170 kV

85 kV

75 kV

195 kV; 145 kV; 85 kV

170 kV; 125 kV; 75 kV

POWER FREQUENCYWITHSTANDVOLTAGE

A) ACROSS THE ISOLATING DISTANCE OF THE FUSE BASE

B) TO EARTH AND BETWEEN POLES

80 kV

70 kV

32 kV

28 kV

80 kV; 60 kV; 32 kV

70 kV; 50 kV; 28 kV

BREAKING CURRENT AT 36/15 kV

6.8 kA

8 kA

6.8 kA; 8 kA

MOUNTING ANGLETOVERTICAL AXIS

20

20

20

TOTAL CREEPAGE DISTANCE

Minimum 900 mm

Minimum 320 mm

Minimum 900; 490; 360 mm

WEIGHT

18 kg (Apx)

8.5 kg (Apx)

6 Kg (Apx.), 5 Kg (Apx.), 4 Kg


Enter Buying Requirement Details
Email Id
Mobile number


Back to top