Product Description

Suitable for single and three phase supply, the Din Type Single Pole Switchable Fuse Switches is manually operated to switch load between power supplies. Customers prefer it to switch from electric power supply to the stand-by supply, thereby ensuring consistent power generation. Operated manually, this switch has the flame retardant body to prevent the chances of accidents due to short-circuiting and over voltage conditions. The purpose of demanding this switch is to allow consistent electricity swapping from the generator to supply and vice versa. It is extensively used in almost every commercial and residential place for handling the current of up to 63 amperes. We procure quality assured materials to manufacture this Din Type Single Pole Switchable Fuse Switches.

Features:
  • For bus bar mounting 250A, 400A & 630A, 415V AC, SIZE 1, 2, 3.
  • Suitable for Single/Triple Pole Switching 
  • They can be used for distribution boards, power control centers, cable, pillar boxes etc. The fuse switches guarantee operational safety against accidental contact and have adequate breaking capacity.
  • It is economical to use vertical type fuse switches in the LV Distribution boards.
Characteristics:
  • The fuse switch can be closed on the short circuit fault without danger to the operator.
  • It utilizes AC 22 as per IEC 60947 category and also high degree of short circuit making capacity.
  • Bit has a glass fiber reinforced polyster (DMC) body.
  • The contacts are of copper Tin/silver plated, spring assisted provided with arc chutes with adequate number of splitter plates for quenching the arc.
  • The downward connections are of electrolytic copper tin plated which are brought to one level at the bottom for cable termination with phase L1 on the left hand side. The hinged front cover is 3x Single Pole/Triple-Pole Switchable.
  • Protection against accidental contact with live parts even if the switch cover is open.
  • HRC Fuse Switches generally meet the requirement of IEC 60947.

Technical specifications

Type/Data

GDVS-3/250A

GDVF-3/400A

GDVF-3/630A

Operating Voltage

415V-50 Hz

500V, 50Hz

500V, 50Hz

Rated Thermal Current

250A , Size 1

400A , Size 2

630A , Size 3

Rated Insulation Voltage

660V

660V

660V

HRC Fuse Links

DIN 43620

DIN 43620

DIN 43620

Short Circuit withstand capacity (Dynamic peak)

10kA

18.62 kA

22.66 kA

Fuze size IEC/DIN

0-1



Weight Without Fuse Links

2.650 Kg

3.405 Kg

4.105 Kg

Short Circuit capacity with HRC fuse links

50 kA (Prospective)

50 kA (Prospective)

50 kA (Prospective)